Complete System of Breathable Membranes
Left Image
WallShield
Unsurpassed in Performance
With a rating of 212 perms, WallShield allows trapped interior moisture to escape reducing the risk of mold, mildew and rot.
Right Image

WallShield Approvals and Testing

Printer Friendly Version (PDF, 30kb)
ICC-ES Approval (PDF, 141kb)

PROPERTYSTANDARD/TESTRESULT
Tensile StrengthASTM D882MD - 28.2 lbf/inch (4.94 N/mm)
CD - 22.6 lbf/inch
PASS
Water Resistance
(control and weathered specimens)
AATCC 127
(55cm hydrostatic head of water for 5 hrs)
No leakage noted on underside of control or weathered samples
PASS
Water Vapor TransmissionASTM E96*
(Method B)
1309.7 g/m² 24hrs
12126.4 ng/Pa/s/m²
212 Perms
PASS
Low Temperature Bend5 specimens bent over a 1/16 inch mandrel at 32ºFNo cracking or de-lamination noted.
PASS


FIRE TESTING

PROPERTYSTANDARD/TESTRESULT
Flamespread IndexASTM E-845 – Class A
PASS
Smoke Development IndexASTM E-8470 – Class A
PASS


INDEPENDENT TESTING

PROPERTYSTANDARD/TESTRESULT
Nominal ThicknessCalibrated Deadweight Micrometer0.023 inch (0.58mm)
Basis WeightElectronic Weigh Scale5.16 oz/yd² (0.55 oz/ft²)
175g/m²
Drying Rate Analysis of Wet Plywood & OSB**

Water Loss (g) Over 100 hrs at 70ºF,

50% RH

280 grams of water vapor lost through WallShield membrane
(four times nearest competitor)

Tested in accordance with ICC-ES AC 38 criteria to meet IBC and IRC requirements for Weather Resistive Barriers (ICC Certificate #ESR-1916).

*ASTM E 96 - Method B (wet cup method) typically gives a more realistic result for permeance of highly permeable products than does the Method A (dry cup/desiccant method).

**Test report available upon request from VaproShield LLC


Printer Friendly Version (PDF, 30kb)
ICC-ES Approval (PDF, 141kb)

REFERENCES
AATCC - American Association of Textile Chemists & Colorists
ASTM - American Society for Testing & Materials
ICC-ES-AC - International Code Council, Evaluation Service Report

 

Third Party Testing Drying Rates Comparisons

VaproShield breathable membranes are unsurpassed in their ability to dry wet sheathing
Third-party testing results clearly indicate the superior drying capability of both WallShield and WrapShield.