slopeshieldsa_thumb

SLOPESHIELD SA® SELF-ADHERED

With a vapor permeance rating of 59 perms, SLOPESHIELD SA® SELF-ADHERED provides the highest breathability in a commercial quality, self-adhering roofing underlayment membrane.

Printer Friendly English (PDF, 976 Kb)

SLOPESHIELD SA® SELF-ADHERED Testing

PROPERTYSTANDARD/TESTRESULT RESULT RESULT
Tensile Strength

ASTM D1682
AC 48, Section 4.1

Control
MD – 106.7 lbf/inch
(18.7 N/mm)
XMD – 83.8 lbf/inch
PASS

Accelerated Aged
MD – 107.0 lbf/inch
(18.7 N/mm)
XMD – 81.4 lbf/inch
PASS
 UV Exposed
MD – 97.3 lbf/inch
(17.0 N/mm)
XMD - 76.7 lbf/inch
PASS

Water Vapor Transmission and Permeance

ASTM E96*
(Water Method)
AC 207, Section 4.1

406.3 g/m² 24hrs
3374.8 ng/Pa/s/m²
59 Perms
PASS

   

Water Ponding

AC 48, Section 4.4
24" head of water for 48 hrs.

PASS    
Accelarated Aging

AC48, Section 4.7
AC207, Section 4.6

PASS    

UV Exposure

AC48, Section 4.8
AC207, Section 4.7

PASS    

Liquid Water Transmission

ASTM D4869
AC207, Section 4.3
Showerhead impinges 40 to 42 gallons of water per hour for 4 hrs on sample.

PASS    

Rupture Resistance

ASTM D3462
AC207, Section 4.4

PASS    

Pliability

ASTM E48
AC 207, Section 4.2

PASS  



INDEPENDENT TESTING

PROPERTYSTANDARD/TESTRESULT
Nominal Thickness Calibrated Deadweight Micrometer 0.020 inch (0.51mm)
Basis Weight Electronic Weight Scale 5.01 oz/yd² (0.55 oz/ft²)
170g/m²

 

Acceptance Criteria for Polypropylene Roof Underlayments AC 207 & Acceptance Criteria for Roof Underlayments for use in severe climate areas AC48. Tested in accordance with ICC-ES AC 48 and AC 207 criteria to meet UBC, IBC and IRC requirements for Roofing Underlayments.

*ASTM E 96 - Method B (wet cup method) typically gives a more realistic result for permeance than does the Method A (dry cut/desiccant) method.


APPLICATION

ROOF SLOPEAPPLICATION
1:12
For slip sheet applications only
2:12 Minimum 12" Horizontal/Vertical Lap Seams
VaproTape™ required under metal clips and similar penetrations
3:12 Minimum 12" Horizontal/Vertical Lap Seams
VaproTape required under metal clips and similar penetrations
4:12 and greater Minimum 6" Horizontal/Vertical Lap Seams
VaproTape is not required for clips

 

Printer Friendly English (PDF, 976 Kb)